7
UK/US
Example
Command programming sequence:
$+ MA0RC1237 $- CR
Enter configuration environment
Carriage return character (0D Hex.)
STAR-Modem address in Stand Alone system: 1237
Exit and Save configuration
Each configuration parameter setting removes the condition previously active for that
parameter.
Refer to the STARModem™ Reference Manual for changing the default
parameters.
STAR
Modem™ SETUP FOR STAND ALONE MODE
STAR
Modem Receiver (Server)
RESTORE DEFAULT
Whenever necessary, send the following string to STARModem™ via RS232 to
restore its default values:
Restore STAR
Modem™ Default
$+$*CR
This command does not change the STARModem™ address nor the RF Baud
Rate parameters.
SET RADIO ADDRESS
Follow the procedure below to set the STARModem™ radio address and prepare it
to receive data from the RF devices of the system:
1.
Enter Configuration
$+
2.
Set STAR
Modem™ Radio Address
xxxx = four digits for the STARModem™ address (from
0000 to 1999). This address must be unique.
MA0RCxxxx
3.
Set RF Baud Rate (not for USA model)
x = 0 defines 9600 baud
1 defines 19200 baud
MFx
4.
Exit and Save Configuration
$-CR
Vedere la pagina 14