Datalogic-scanning Rhino-NET 40012 Manuale Utente Pagina 1

Navigare online o scaricare Manuale Utente per Hardware Datalogic-scanning Rhino-NET 40012. Datalogic Scanning Rhino-NET 40012 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
TM
Rhino-NET
Users Manual
www.mobile.datalogic.com
Datalogic Mobile S.r.l.
Via S. Vitalino, 13
40012 Lippo di Calderara di Reno
Bologna - Italy
Telephone: (+39) 051-3147011
Fax: (+39) 051-3147561
World wide Sales Network
available from: www.mobile.datalogic.com/contacts
©2008 Datalogic Mobile S.r.l.
822000494 (Rev. E)
07/08
Vedere la pagina 0
1 2 3 4 5 6 ... 52 53

Sommario

Pagina 1 - User’s Manual

TMRhino-NET User’s Manualwww.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340012 Lippo di Calderara di RenoBologna - ItalyTelephone:

Pagina 2

WEEE COMPLIANCE Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barra

Pagina 3 - CONTENTS

Benutzerinformation bezüglich Richtlinie 2002/96/EC der europäischen Kommission Am Ende des Gerätelebenszyklus darf das Produkt nicht über den städ

Pagina 4

GENERAL VIEW Figure A - Rhino-NET™ Components B A F G DI H E CB A. PC Card Slots B. Speaker/Beeper C. CapsLock Indicator D. Power Status Ind

Pagina 5 - REFERENCES

QUICK START Verify that Rhino-NET™ and all the parts supplied with the equipment are present and intact when opening the packaging. Contact the nea

Pagina 7 - Information for the User

INTRODUCTION 11 INTRODUCTION 1.1 RHINO-NET™ DESCRIPTION Rhino-NET™ is a Datalogic vehicle mounted RF terminal of the mobile@work™ family with Windo

Pagina 8

RHINO-NET™ 1 1.3 AVAILABLE MODELS Rhino-NET™ is available in different versions depending on whether an onboard radio and bluetooth module are prese

Pagina 9 - BLUETOOTH® APPROVAL

INTRODUCTION 1 ⒷⒶFigure 2 - The Rhino-NET™ PCMCIA Slots 1.7 POWER SUPPLY Vehicle power input for the Rhino-NET™ can range from 11 to 60VDC and is a

Pagina 10 - WEEE COMPLIANCE

RHINO-NET™ 1 1.8 BLUETOOTH® MODULE Rhino-NET™/RF-3 EU BT Low Temp model is equipped with a Bluetooth® module for radio communications to other devic

Pagina 11

INSTALLATION 22 INSTALLATION Rhino-NET™ has been designed for fast and easy mechanical installation. Rhino-NET™ can be mounted either to the roof,

Pagina 12 - GENERAL VIEW

Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 – Lippo di Calderara di Reno Bologna – Italy Rhino-NET™ – User's Manual Ed.: 07/2

Pagina 13 - QUICK START

RHINO-NET™ 2 4 Position Rhino-NET™ at the bottom of the bracket: make sure the two large round openings coincide to the ones located at the edges of

Pagina 14

INSTALLATION 22.3 MOUNTING TO FORKLIFT FLOOR This type of installation may decrease the range of the radios located in the bottom of the Rhino-NET™

Pagina 15 - 1 INTRODUCTION

RHINO-NET™ 2 Figure 7 - Rhino-NET™ in Vehicle Bracket Rhino-NET™ is now ready. 2.4 POSITIONING Rhino-NET™ can rotate on its mounting bracket up

Pagina 16 - 1.5 KEYBOARD

INSTALLATION 2 Set pin screwFigure 9 - Rhino-NET Side View with Punched Steel Ring and Relative Set Pin Screw 9

Pagina 17 - 1.7.1 Backup Batteries

RHINO-NET™ 2 2.5 CONNECTING POWER CAUTION For proper and safe installation, the input power cable must be connected to a fused circuit on the vehic

Pagina 18 - 1.9 CONNECTORS

INSTALLATION 2 CAUTION For uninterrupted power, electrical supply connections should not be made at any point after the ignition switch of the vehicle

Pagina 19 - 2 INSTALLATION

RHINO-NET™ 2 Figure 11 - Connect Power Cable to Rhino-NET™ 6. Turn the Rhino-NET™ on. 12

Pagina 20 - RHINO-NET™

INSTALLATION 22.6 CONNECTING A SERIAL BARCODE SCANNER Refer to the documentation received with the barcode scanner for complete instructions. Read al

Pagina 21 - INSTALLATION

RHINO-NET™ 2 For 2D code reading, the Lynx™ readers are the most suitable readers for the Rhino-NET™ environment: - connect it with external power s

Pagina 22 - 2.4 POSITIONING

INSTALLATION 22.8 CONNECTING A SERIAL DEVICE Rhino-NET™ can be connected to several types of serial devices through its COM1 port such as: serial pr

Pagina 23

CONTENTS REFERENCES ...v Conventions...

Pagina 24 - 2.5 CONNECTING POWER

RHINO-NET™ 3 3 USE AND OPERATION 3.1 POWERING ON/OFF Connect the Rhino-NET™ to a power source, either Vehicle battery (see par. 2.5) or an AC ADA

Pagina 25

USE AND OPERATION 33.2 KEY DESCRIPTIONS The Rhino-NET™ ABCD keyboard facilitates data input. The keyboard includes two special keys: FUNC (green) an

Pagina 26

RHINO-NET™ 3 3.2.2 Keyboard LEDs The Rhino-NET™ keyboard has two LED indicators. Power LED Indicator CAPS Lock Mode LED Indicator Figure 18 - Key

Pagina 27

USE AND OPERATION 33.3.1 Hardware Reset In case the Rhino-NET™ terminal locks up and cannot be unlocked a hardware reset can be performed as follows:

Pagina 28 - 94ACC1289) for a correct

RHINO-NET™ 3 3.5 CONTROL PANEL The main window of the Windows® CE Control Panel is shown below as it appears on the terminal when launched from Star

Pagina 29

USE AND OPERATION 33.5.2 Files Admin The FILES ADMIN applet enables control of the permanence of files in the System Folder. Two functions are availa

Pagina 30 - 3 USE AND OPERATION

RHINO-NET™ 3 Figure 24 - Safe Setup Second Mask 3.5.3 Scanner Setup This applet contains terminal and barcode scanning configuration parameters

Pagina 31 - 3.2.1 Control Keys

USE AND OPERATION 3For a detailed list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD-ROM. Figure

Pagina 32 - 3.3 RESET (REBOOT)

RHINO-NET™ 3 Scan Timeout: the maximum time, in milliseconds, during which Rhino-NET™ accepts data from the port after a Soft Trigger. Beep Duration

Pagina 33 - 3.3.2 Software Reset

USE AND OPERATION 33.5.4 Bluetooth Manager Device Setup In order to enable a Bluetooth device for communication with the Rhino-NET™/ RF-3 EU BT Low

Pagina 34 - 3.5.1 Registry Admin

3.5.2 Files Admin...21 3.5.3 Scanner

Pagina 35 - 3.5.2 Files Admin

RHINO-NET™ 3 3.6 BARCODE READING Follow the procedure below and choose one of the methods indicated at step 3 to enable the Rhino-NET™ to receive ba

Pagina 36 - Reader Parameters

USE AND OPERATION 33.8 MICROSOFT® ACTIVESYNC® Microsoft® ActiveSync® gives you the possibility to connect your desktop computer to your Rhino-NET™ te

Pagina 37 - Scan Parameters

RHINO-NET™ 3 To activate this feature, open the Control Panel and run the PC Connection icon: Figure 29 - PC Connectin Properties To make these s

Pagina 38 - Default Settings

USE AND OPERATION 3directory doesn't exist originally (only Backup exists), and therefore it must be created. At the next hardware reset, before

Pagina 39 - USE AND OPERATION

RHINO-NET™ 4 4 MAINTENANCE 4.1 CLEANING RHINO-NET™ Periodically clean Rhino-NET™ terminal with a slightly dampened cloth. Repeat the operation fre

Pagina 40 - 3.7 REMOTE DISPLAY

TROUBLESHOOTING 55 TROUBLESHOOTING CAUTION The only internal components that personnel not belonging to Datalogic or ARC technical support can add

Pagina 41 - 3.8 MICROSOFT® ACTIVESYNC®

RHINO-NET™ 5 Problem Possible Solution The barcode reader (either Laser or CCD) emits no light source. Check whether one of the following conditions

Pagina 42

TECHNICAL FEATURES 66 TECHNICAL FEATURES Electrical Features Power Internal wide range power supply (11-60 VDC) Transient spike and over current/vo

Pagina 43

RHINO-NET™ 6 Accessories Mounting brackets Included in this package Mounting kit to secure the terminal to the mounting bracket. Included in this p

Pagina 44 - 4 MAINTENANCE

GLOSSARY Access Point (AP) A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped m

Pagina 45 - 5 TROUBLESHOOTING

REFERENCES CONVENTIONS This manual uses the following conventions: "User" or "Operator" refers to anyone using a Rhino-NET™ t

Pagina 46

Flash Disk Non-volatile memory for storing application and configuration files. Host A computer that serves other terminals in a network, providing

Pagina 47 - 6 TECHNICAL FEATURES

INDEX A Available Models; 2 B Backup Directory File Management; 28 Barcode Reading; 26 Battery Warning Messages; 19 Bluetooth®; 4 C Connections Con

Pagina 48 - 94ACC1289

Datalogic Mobile S.r.l., Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy 07 dichiara che declares that the déclare que le be

Pagina 49 - GLOSSARY

TMRhino-NET User’s Manualwww.mobile.datalogic.comDatalogic Mobile S.r.l.Via S. Vitalino, 1340012 Lippo di Calderara di RenoBologna - ItalyTelephone:

Pagina 50

SAFETY REGULATIONS NOTE Read this manual carefully before performing any type of connection to the Rhino-NET™ mobile computer. The user is respons

Pagina 51

RADIO COMPLIANCE Information for the User ENGLISH Contact the competent authority responsible for the management of radio frequency devices of your

Pagina 52 - 1999/5/EEC R&TTE

VEHICLE POWER SUPPLY CONNECTION SAFETY STATEMENT ENGLISH Vehicle Power Supply Connection: If the supply connection is made directly to the battery,

Pagina 53

ESPAÑOL Conexión de suministro eléctrico para el vehículo: Si el suministro eléctrico se proporciona directamente a la batería, se debe instalar un f

Commenti su questo manuale

Nessun commento