Datalogic-scanning POWERSCAN 7000 Manuale Utente Pagina 28

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 204
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 27
Terminal Interfaces
2-10 PowerScan
®
7000 2D
RS-232 Receiver Time-Out
The unit stays awake to receive data until the RS-232 Receiver Time-
Out expires. A manual or serial trigger resets the time-out. When an
RS-232 receiver is sleeping, a character may be sent to wake up the
receiver and reset the time-out. A transaction on the CTS line will also
wake up the receiver. The receiver takes 300 milliseconds to completely
come up. Change the RS-232 receiver time-out by scanning the bar
code below, then scanning digits from the
Programming Chart on page B-
5
of this manual, then scanning Save. The range is 0 to 300 seconds.
Default = 0 seconds (no time-out - always on).
RS-232 Receiver Time-Out
Vedere la pagina 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 203 204

Commenti su questo manuale

Nessun commento